WAREMA climatronic®

The WAREMA climatronic® is a complete solution to controlling all WAREMA products as well as other systems in your building.

Whatever the season, WAREMA climatronic® will lower your energy consumption and make sure the climate is just right.

  • Operation
    WAREMA climatronic® 3.0 control panel
    The control panel for the WAREMA climatronic® system processes incoming data from connected sensors, coordinates these with the individual settings and forwards commands to the actuators via the Climabus.
    - Direct operation at home using the WLAN network (or LAN network) - Rail-mounted device is connected to the control panel via the controlbus and to a router - Operation using a free app for devices with the iOS or Android operating system - Operation via universal browser application - SD card for saving the configuration & updating firmware
  • Sensors
    WAREMA climatronic® weather station
    Weather station for the WAREMA climatronic® system.
    WAREMA climatronic®Sensor Inside temperature/Humidity
    - Converts the physical measured values into electronic signals for evaluation in WAREMA climatronic - Functions: - Temperature-dependent: Sun shading system only moves in the desired direction when the temperature programmed in the WAREMA climatronic has been reached in the room - Humidity-dependent: If the limit values stored in the WAREMA climatronic are exceeded, a window can be automatically opened or a fan can be switched on, for example
    WAREMA climatronic® Sensor Interface AP/REG
    - Alternatives or additional components to the WAREMA climatronic® weather station - Up to 3 weather stations or Sensor Interfaces can be connected to one WAREMA climatronic® - The following sensors can be connected to a Sensor Interface: - 4 photo sensors - 1 global radiation sensor - 1 dawn/dusk sensor - 4 wind speed sensors - 1 wind direction sensor - 1 outside temperature sensor - 1 precipitation sensor - 1 relative humidity sensor - 1 DCF77 radio module - Protection-relevant data, such as wind and precipitation, are read once per second - Data such as brightness, dawn/dusk and radio clock signals are transmitted every 10 seconds - Sensor Interface is supplied and connected via the climabus - Additional power supply units required for heatable sensors (e.g. Wind and Precipitation) Note: External power supply unit required!
  • Switch actuators for 230 V drives (external sun shading systems and lighting)
    WAREMA climatronic® switch actuator 4/6M230, AP/REG
    Switch actuator for the control of drives in the WAREMA climatronic® system.
    WAREMA climatronic® switch actuator 4/6M, AP/REG
    Floating switch actuator for the control of drives in the WAREMA climatronic® system
    WAREMA climatronic® switch actuator 4M230I for external venetian blinds with vivamatic®
    Actuator for the centralised and localised operation of up to four independently operated sun shading drives.
    WAREMA climatronic® switch actuator 16M230 SMI
    Actuator for central and local operation of up to 16 x 230 V AC SMI sun shading products.
  • Switch actuators for 24 V drives (internal sun shading systems)
    WAREMA climatronic® switch actuator 4MDC AP/REG
    Actuator for the centralised and local operation of up to four independently operated 24 V DC sun shading drives.
  • Additional components for WAREMA climatronic®
    Switching power supply 24 V, 2.5 A
    - Power supply unit available in several models: - Surface mounted - Rail mountingNote: The parallel connection of multiple switching power supplies is not permitted!
    WAREMA climatronic® Tableau Interface AP/REG
    - Connected switches/push buttons can be freely assigned to channels, groups and scenes - Assignment is comfortable using the WAREMA climatronic® studio software - Tableau Interface Master provides 48 inputs - System can be expanded up to 144 inputs with max. 4 Tableau Interface Slaves - Tableau Interfaces are connected to one another via a separate slave bus (RS485) - Power supply - Tableau Interface Master: separate power supply unit - Tableau Interface Slave: slave bus connection (from master) Note: External power supply unit required!
    WAREMA climatronic®Dim actuator 2D
    - Dimming of up to two ohmic, inductive and capacitive loads (230 V AC) - Set brightness is stored when the actuator switches off and is restored when it switches on again - Regulates speed of fan drives from different manufacturers - To control fans with damper flaps, one additional 230 V AC contact is provided per output - Damage to connected power consumers is prevented by soft-start and soft-stop at the zero crossing - Inputs for connecting light push buttons for local operation - Operating mode of connected local push buttons is automatically adjusted to the product set for the channel Notes: - It is not possible to dim LED lamps or fluorescent lamps with the dim actuator 2D. Switching and dimming mixed loads (R/L/C) on one output is not permitted. - External power supply unit required! - Before using the actuator, check whether the fan being used is supported.
    WAREMA climatronic Repeater climabus
    - Repeater and HUB have a different number of independent outputs - Repeater: 1 output - HUB: 3 outputs - Cascading of up to two Repeaters or HUBs - WAREMA climatronic® systems with 100 or more actuators require one Repeater per 100 devices - A Repeater is not required for fewer than 100 devices, except in the case of a line extension - Communication from one HUB output to another is not possible Note: external power supply unit required
    WAREMA climatronicHUB climabus
    - Repeater and HUB have a different number of independent outputs - Repeater: 1 output - HUB: 3 outputs - Cascading of up to two Repeaters or HUBs - WAREMA climatronic® systems with 100 or more actuators require one Repeater per 100 devices - A Repeater is not required for fewer than 100 devices, except in the case of a line extension - Communication from one HUB output to another is not possible Note: external power supply unit required