The floor distribution control Standard controls motor control units for up to 4 facades or groups via a higher-level central control unit or for facades with operation on different stories.

Completely controlled by level

Control on the channel or the facade with 4 outputs: up to 4 facades or grouped motor control units per level can be controlled.

Manually operable

Dead man operating mode: the move command is executed for as long as the push button is actuated.

Simplified

Clear structures give you an overview of the required wiring: the system optimises the required wiring in complex buildings.

  • Floor operation of up to 4 facades via connectable venetian blind switches
  • Dead man operating mode executes move command as long as the switch is actuated
  • Supplies power to control devices without an integrated power supply unit (e.g. MSE Piccolo, Uniswitch ZL)
  • 4 non-floating outputs (24 V DC, max. 2 A)
Article number: 1002253

Description

Value

Operating voltage

230 V AC

Control voltage

24 V DC

Output

4 x 24 V DC

Switching capacity per drive

2 A at 24 V DC

Logic behaviour

Dead man

Degree of protection

IP 54

Safety class

II

Type of installation

Surface-mounted (AP)

Width

240 mm

Height

160 mm

Depth

90 mm