Completely controlled by level
Control on the channel or the facade with 4 outputs: up to 4 facades or grouped motor control units per level can be controlled.
Manually operable
Dead man operating mode: the move command is executed for as long as the push button is actuated.
Simplified
Clear structures give you an overview of the required wiring: the system optimises the required wiring in complex buildings.
- Floor operation of up to 4 facades via connectable venetian blind switches
- Dead man operating mode executes move command as long as the switch is actuated
- Supplies power to control devices without an integrated power supply unit (e.g. MSE Piccolo, Uniswitch ZL)
- 4 non-floating outputs (24 V DC, max. 2 A)
Description
Value
Operating voltage
230 V AC
Control voltage
24 V DC
Output
4 x 24 V DC
Switching capacity per drive
2 A at 24 V DC
Logic behaviour
Dead man
Degree of protection
IP 54
Safety class
II
Type of installation
Surface-mounted (AP)
Width
240 mm
Height
160 mm
Depth
90 mm