The emergency power supply kit from WAREMA is a comfort control intended to ensure that sun shading products are raised in the event of a power supply interruption.

Fail-safe

A reliable system: the emergency power supply kit permanently runs a functional check and triggers in the event of an internal malfunction.

Safe

Protection in the event of a power failure: the emergency power supply kit ensures that sun shading products can be raised if the power supply is interrupted, ensuring clear escape routes.

Ready for use

Automatic reset: after activation, the system automatically switches to regular control mode. 

  • The emergency power supply kit is a comfort control intended to ensure that sun shading products are raised in the event of a power supply interruption.
  • The emergency power supply kit consists of an uninterrupted power supply (UPS) emergency power supply kit and at least one motor control unit (MSE) emergency power supply kit (sold separately).
  • An MSE emergency power supply kit is connected upstream of the 230 V drive.
  • Depending on the power input per drive, up to 4 MSE emergency power supply kits are connected to one UPS.
  • Connection of a motor control unit or actuator for controlling the sun shading product via a central control unit or a push button on site.

  • Connection of a push button on site to activate "alarm raising".

  • Connection of a key-operated switch or connection to on-site BCS for resetting.

  • Issuing of fault signals.

  • The following signals activate raising:
    • Mains voltage failure
    • Activated via contact of the building control system (GLT) e.g. fire alarm system
    • Activated by Up button on site
    • Empty, faulty or old storage batteries
    • UPS overload
    • Internal UPS fault
Article number: 2013984

Description

Value

Operating voltage

230 V AC

Safety class

I

Width

137 mm

Height

158 mm

Depth

358 mm

Fixing bracket for uninterrupted power supply (UPS) on the wall or ceiling

Push button to connect to MSE emergency power supply kit to activate the UP command

Surface-mounted housing for push button for emergency power supply kit

Key-operated switch to connect to MSE emergency power supply kit as reset button