• Potential isolation for long control lines
  • Formation of additional local groups in conventional controls
  • ZL: In time mode, the MSE enters lock mode after the push button is pressed for approx. 2 seconds. Operating the push button briefly generates a tilting impulse (on slat products).
  • Central control line (24 V) supplies power to the uniswitch.
  • Downstream motor control units can still be operated via local push buttons or via a central control unit
  • Compact design enables installation in a flush-mounted box.
Article number: 1002473

Description

Value

Operating voltage

24 V DC

Control voltage

24 V DC

Output

Floating

Switching capacity per drive

72 W

Logic behaviour

ZL

Degree of protection

IP 20

Safety class

III

Type of installation

Flush-mounted (UP)

Width

48.5 mm

Height

48.5 mm

Depth

20.4 mm